Response Stage: Trillium-240 Generation 2 PZ

Name:Trillium-240 Generation 2 PZCorrection:
Stage Index:1Sample Offset:0.0
Stage Type:Poles & ZerosDecimation:1.0
Input Units:M/SInput Sample Rate:
Output Units:VGain:1189.0000000
Transfer Function Type:ContinuousGain Frequency:1.0
Delay:0 sSymmetry:None

Poles & Zeros

There are 17 poles & zeros.

Type Index Value Action
Pole 1 -0.01770+0.01760i
Pole 2 -0.01770-0.01760i
Pole 3 -85.30000+0.00000i
Pole 4 -155.40000+210.80000i
Pole 5 -155.40000-210.80000i
Pole 6 -713.00000+0.00000i
Pole 7 -1140.00000+0.00000i
Pole 8 -4300.00000+0.00000i
Pole 9 -5800.00000+0.00000i
Pole 10 -4300.00000+4400.00000i
Pole 11 -4300.00000-4400.00000i
Zero 1 0.00000+0.00000i
Zero 2 0.00000+0.00000i
Zero 3 -72.50000+0.00000i
Zero 4 -159.30000+0.00000i
Zero 5 -251.00000+0.00000i
Zero 6 -3270.00000+0.00000i